Product Category
Products
-
INSTALLATION DEVICES
-
MINIATURE CIRCUIT BREAKERS
-
RESIDUAL CURRENT CIRCUIT BREAKER
-
RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION
-
SMART CIRCUIT BREAKER
-
ISOLATORS
-
FUSE HOLDERS AND DISCONNECTORS
-
ACCESSORIES FOR INSTALLATION DEVICES
-
SOCKETS AND SIGNAL LAMPS
-
SURGE PROTECTION DEVICES
-
TIMERS AND LIGHT INTENSITY SWITCHES
-
ENERGY METERS
-
-
INDUSTRIAL DEVICES
-
MOULDED CASE CIRCUIT BREAKERS
-
NEW ENERGY COMPONENTS AND SOLUTION
Number of views:
1000
DB6L
Retail price
0.0
元
Market price
0.0
元
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
General
Parameters
Catalog
Certificate
Drawings
Model |
DB6L |
Poles | 1P,1P+N,2P,3P,3P+N,4P |
Electrical Specifiction | 1-63 |
Rated current(A) | 1P:230/400~. 2/3/4P:400~ |
Rated working voltage(V) | 500 |
Rated insulated voltage(v)ui | 6 |
lmpulse withstand voltage(kv) | 6 |
lnstantaneous tripping type | B,C,D |
Maximum working voltage | 440 |
Dielectric test voltage(kv) | 2 |
Mechanical Standard value | 10000 |
Mechanical Standard value | 4000 |
Control And Indication | / |
Shunt release(SHT) | / |
Undervoltage release(UVT) | / |
Auxiliary contact(AUX) | / |
Alarm contact(ALT) | / |
Contact position indicatorFault indication | / |
Connection And lnstallation | / |
Ambient temperature(with daily averages35℃) | -5℃ ~+40℃ |
ALL sides | IP40 |
Connection terminal | IP20 |
Wire(mm2) | 1-16 |
busbar(mm3) | 25 |
Mounting | Cable/Busbar |
Pollution degree | 2 |
Pollution degree | 30 |
Reference temperature for setting of thermal element(c) | -25℃ ~+70℃ |
Connection | Top and Bottom |
Message
客户留言
Describe:
Related products
PR8HM
Comply with the standard: IEC/EN 61008-1
Product Poles:2P,4P
Rated current: 16-63A
Rated short-circuit breaking capacity:10KA
Rated working voltage: 2P:230V,4P:400V
Residual current working type: AC,AC+S,A
Residual current Protection type: Electronic
Mechanical: 4000
Electrical: 2000
PR8HE
Comply with the standard: IEC/EN 61008-1
Product Poles:2P,4P
Rated current:16-63A
Rated short-circuit breaking capacity:10KA
Rated working voltage:2P:230V,4P:400V
Residual current working type:AC,AC+S,A
Residual current Protection type: Electronic
Mechanical life: 4000
Electrical life: 2000
PN8H
Comply with the standard: IEC/EN 60898-1
Product Poles: 1P+N
Rated current: 1-63A
Rated frequency: 50/60Hz
Rated short-circuit breaking capacity: 6KA
Rated working voltage: 230V
Instantaneous tripping type:B,C,D
Mechanical: 10000
Electrical: 4000
PB8H
Comply with the standard: IEC/EN 60898-1
Product Poles: 1P,2P,3P,4P
Rated current: 1-63A
Rated frequency: 50/60Hz
Rated short-circuit breaking capacity: 10KA
Rated working voltage: 1P:230/400V,2/3/4P:400V
Instantaneous tripping type:B,C,D
Mechanical life: 10000
Electrical life: 4000
Message
客户留言
Description: